ActiGraph System Includes:
|
|
|
|
·
ActiGraph 71xxx Series
· Belt
· Reader Interface Unit
· Wrist Strap
· ActiSoft Analysis Software
· Pouch
|
|
|
|
|
|
AM7164
: Activity Monitor (Actigraph)
|
|
|
|
|
Quantity Cost breaks
available for all models.
|
-
71256-T
256K RAM; Temperature Probe designed to monitor the skin temperature under the ActiGraph. The temperature data replaces the PEDO data in 71256 model.
-
Placebo Model
looks and weighs the same as a functional model.
|
-
71256-L
256K RAM; This version has an ambient light sensor in place of the Pedo mode. The ActiGraph is setup to measure up to 3000 LUX down, focusing on indoor light levels.
|
|
RIU-41A(USB)
: Reader Interface Unit
|
The ActiGraph Reader Interface Unit is used to initialize the ActiGraph and to download data. This is done via an infrared sensor located in the ActiGraph. The Reader Interface Unit attaches to your PC via a serial cable (or USB port). Included with the Reader Interface Unit is the Software, Power Cable, and PC serial port cable. USB Adapter option is available.
|
ActiSoft Version 3.
2
Available Now!
|
Included with the RIU41
:
Operators Manual,
Software
*, Power Cable, and PC cable.
|
|
BP304C
&
BP304
Nylon Pouches
|
|
The pouch is intended to hold the Actigraph on a persons belt, the ribbon loops around the belt and is held by Velcro™.
The pouch provides a layer of protection to the Actigraph as it hides it, making less noticeable.
|
|
|
|
|
CAL71
: Actigraph Calibrator
|
|
Includes:
PC Cable, Software, Power Cable, Adjustment Screw Driver, Calibration Lid, and Operators manual.
Description:
The ActiGraph Calibrator is used to ensure accurate calibration and is recommended for customers with large ActiGraph inventories. The ActiGraph Calibrator attaches to your PC via a serial cable The ActiGraph Calibrator includes serial port connector, Software, Power Cable, Adjustment Screw Driver, Calibration Lid, and Operators Manual.
|
Specifications:
The Calibrator is 12” X 6” X 4” and weighs about 8 pounds.
The frequency range of the calibrator varies from about 3.00Hz to 0.50Hz.
Power requirements
:
The Calibrator has an internal power supply with the variable input (85-264VAC at 47-63Hz or 120-370VDC)
|
|
|
ACCESSORIES
|
|
|
|
Belt
EW36-S/EW48-S/EW60-S:
(Elastic)
NW36-S/NW48-S/NW60-S:
(Nylon)
Belts come with adjustable side release buckles. Belts come in blackand are 1" wide. Sizes come in 36", 48" and 60", but can be customized to any length.
BC386: Belt Clip
Simple and Sturdy. Tapered inside edges to eliminate snagging. 2 3/8" Long X 5/8" wide. Color Black.
|
|
|
|
-
PT408 (European):
:
Replacement Power Module for the RIU40
|
PT402 (USA)
:
Replacement Power Module for the RIU40
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|